We have added a vent calculator to ensure that you purchase the correct size fireplace and a safe installation can be done according to SANS 10087-1.
First calculate the room volume that the unit will be installed into.
Length
x
m x
Width
x
m x
Height
m
m
Next we determine the heat or energy output of the fireplace you want to purchase, calculated in MJ.
kg / Hour x 50
An allowance is made of 0.25MJ heat input per 1m³ of the room volume, before permanent ventilation is required.
Room Volume m³ ÷ 4
Determine if ventilation is required
If the megajoule output of the fireplace exceeds the MJ of the allowance of the room volume, permanent ventilation is required.
If the allowance is greater than that of the MJ output of the fireplace, permanent ventilation is not required.
For flue-less (no chimney) add 6.5cm² of the ventilation per cubic meter (1m³) of room volume and flued (chimney) add 3.0cm³ of the ventilation per cubic meter (1m³) of the room volume.
Room Volume m³ x 6.5cm²
Room Volume m³ x 3.0cm²